Adding a battery to existing solar panels
Whether a battery can be added depends on the exact inverter model and firmware and on the batteries that the inverter manufacturer lists as compatible. A hybrid inverter can often take a compatible battery directly. A standard grid-tied inverter usually needs a separate AC-coupled battery system, or the inverter must be replaced.
A photo of the inverter label is the quickest way for us to check this before quoting. Take it from where you can stand safely; do not remove covers.
New solar and battery systems
When panels, inverter and battery are designed together, the battery size can be based on your actual consumption pattern rather than on a standard package. If you may want more storage later, we choose equipment whose manufacturer documents how it can be expanded, and explain those limits in the quotation.
Essential-circuit backup or wider home backup
A battery does not automatically keep the lights on in a power cut. For safety, a grid-connected inverter shuts down when the grid fails unless the system was designed for backup. Backup needs compatible equipment with a backup output or switching arrangement, isolation from the grid so nothing is fed back into the network, the correct configuration, and the specific circuits connected to that backup supply.
Essential-circuit backup moves selected circuits — for example the fridge, some lighting, the router and the alarm — onto a separate backup board. Wider home backup covers more of the house but needs more inverter output and battery capacity, and large loads such as air conditioning, pool pumps or ovens may still need to be excluded or limited. Switchover behaviour depends on the equipment, so a short interruption may occur.
Usable capacity (kWh) and output (kW)
Capacity in kilowatt-hours (kWh) is how much energy the battery can deliver; output in kilowatts (kW) is how much power it and the inverter can supply at the same moment. Usable capacity is lower than the nominal figure once the reserve and manufacturer limits are applied. A large battery behind a small inverter can still fail to run several heavy appliances together, so we size both from your loads.
Exact inverter and battery compatibility
The battery must be approved by the inverter manufacturer for that specific model, including the battery voltage class (low-voltage, around 48 V, or high-voltage) and the communication link between them. Two products from the same brand are not automatically compatible. We check the current manufacturer documentation for the exact models before quoting.
Three-phase supplies and motor starting loads
Many villas have a three-phase supply. Some inverters are single-phase and some are three-phase, and the backup output may serve one phase or all three. Three-phase equipment such as some pool pumps or air-conditioning units will not run from a single-phase backup supply.
Motors in pumps, compressors and lifts draw a much higher current for a moment when they start. The inverter's short-term (surge) rating has to cover these starting loads, which is checked against the actual equipment.
Installation costs and what the quotation includes
There is no single price, because the scope changes with the existing installation, the backup requirement and access. Your written quotation lists the battery model and usable capacity, any inverter or interface work, protection devices, cabling and mounting, any backup-board work, commissioning, monitoring set-up and the documentation that applies to the job.
Eligibility for grants or tax relief requires a current official check. Our quotations do not assume or deduct any funding.
Commissioning, documentation, monitoring and aftercare
Commissioning covers checking the connections and settings (such as the reserve level and charging rules) and, where backup has been installed, testing that the backup circuits operate as designed. At handover you receive the equipment models and serial numbers, the settings used and the electrical documentation required for the scope of the work.
Monitoring through the manufacturer's app depends on the equipment and a working internet connection. If something goes wrong later, contact us with the inverter display or app message and we will arrange the next step.
Manufacturer warranty and labour support
The equipment warranty comes from the manufacturer and its terms depend on the model — for example the period, energy throughput, capacity retention and installation conditions. Labour support for our own work is separate and its terms are written into your quotation. Ask to see both before you decide.
Physical batteries and virtual billing credits
Some electricity retailers offer a 'virtual battery': surplus solar exported to the grid is credited in euros against later bills. It is a contract feature, not equipment. It provides no backup during a power cut, and its value depends on the retailer's credit rate, expiry rules, fees and what the credit can be used against. Compare those terms with the cost of a physical battery for your own consumption.